FixVault
Home
›
Kia
›
2021
›
Seltos LX
›
Repair and Diagnosis
›
Engine Performance
›
Engine Control Systems
›
Engine Control System - 2.0L
›
CVVT Oil Control Valve (OCV)
›
Repair Procedures
›
Removal
›
Intake
Repair Procedures: Removal: Intake
Disconnect the negative battery terminal.
Disconnect the CVVT oil control valve connector (A).
Remove the CVVT oil control valve after loosening the mounting bolt (B).
Tightening torque
:
9.8 - 11.8 N.m (1.0 - 1.2 kgf.m, 7.2 - 8.7 lb.ft)
Courtesy of KIA MOTORS AMERICA, INC.