FixVault

Basic Inspection: Notes

WARNING: EV battery system uses high voltage.
It may cause death or damage due to electrical shock, if you do not follow below Instructions.
  • Follows instructions of workshop Service Information.
  • Wear and use insulated gloves and tools.
  • Ignition "OFF", disconnect ground cable of 12V battery, Open lower-voltage junction block cover which is in PE room and wait 5 minutes after disconnect A/S interlock. (Blocking high voltage electronic)
  • Check high voltage terminal on power relay assembly is lower than 30V.
  • Be careful that it should not be short between terminals when measuring battery cell voltage. You may be injured due to spark, parts damage or electrical shock.
  • Metallic material cause high voltage short that may cause damage of life or vehicle. Therefore, get rid of all the metallic material before working. (Metallic Material: Watch, Ring, any metallic products etc.)
  • After disconnect high voltage cable, be careful not to happen short between exposed terminals on high voltage connector.