FixVault

Component Inspection

Inspection Condition (+) Probe (-) Probe Specification
Connector Terminal Connector Terminal
  1. Ignition "OFF".
  2. Disconnect the electrical connector(s) from the concerned component.
Knock sensor #2 (component side) 2 (signal) Knock sensor #2 (component side) 1 (ground) Approx. 3.90 to 5.84MΩ (20°C

Good 

No Good