FixVault

Module Inspection

Inspection Item Inspection Condition (+) Probe (-) Probe Specification
Connector Terminal Connector Terminal
Power inspection (VCU ↔ Chassis ground)
  1. Disconnect the VCU connector.
  2. Ignition "ON".
VCU connector (2WD) 18, 19, 66, 68 (power) Chassis ground - B+
VCU connector (4WD) 6, 51, 67, 73, 87 (power) Chassis ground - B+
Open in circuit inspection (VCU ↔ Chassis ground)
  1. Ignition "OFF".
  2. Disconnect the VCU connector.
VCU connector (2WD) 65, 67 (ground) Chassis ground - Approx. below 1Ω
VCU connector (4WD) 4, 7, 29, 68 (ground) Chassis ground - Approx. below 1Ω

Good 

No Good