DTC Information: DTC Detecting Condition

Item Detecting Condition Possible Cause
DTC Strategy
  • Electrical check
  • Poor connector connection
  • Open in HO2S control circuit
  • Front HO2S
Enable Conditions
  • Sensor ceramic temperature is greater than 640°C (1184°F)
  • Sensor forced stimulation active
  • Normal 12V battery voltage (11 to 16V)
  • Sensor operative readiness detected
Threshold Value
  • Pumping cell resistance value is higher than 323Ω
  • When the difference between the pumping cell voltage and the virtual ground line is less than 1.2V
  • When the difference between the nernst cell voltage and the virtual ground line is higher than 1.2V
Diagnostic Time
  • Continuously
MIL ON Condition
  • 2 driving cycles