Module Inspection

Inspection Item Inspection Condition (+) Probe (-) Probe Specification
Connector Terminal Connector Terminal
Power inspection (HPCU ↔ Chassis ground)
  1. Disconnect the connector(s) HPCU.
  2. Ignition "ON".
HPCU connector 15, 16, 30, 31, 32, 62 (power) Chassis ground - B+
Open in circuit inspection (HPCU ↔ Chassis ground)
  1. Ignition "OFF".
  2. Disconnect the connector(s) HPCU.
HPCU connector 47, 48, 63, 64 (ground) Chassis ground - Approx. below 1Ω

Good 