FixVault

Module Inspection

Inspection Item Inspection Condition (+) Probe (-) Probe Specification
Connector Terminal Connector Terminal
Power inspection (ICU ↔ Chassis ground)
  1. Disconnect the connector(s) ICU.
  2. Ignition "ON".
ICU connector 1, 2, 15, 17, 21, 26, 38, 54 (power) Chassis ground - B+
Open in Circuit Inspection (ICU ↔ Chassis ground)
  1. Ignition "OFF".
  2. Disconnect the connector(s) ICU.
ICU connector 13, 14 (ground) Chassis ground - Approx. below 1Ω

Good 

No Good