FixVault

Module circuit Inspection

Inspection Condition (+) Probe (-) Probe Specification
Connector Terminal Connector Terminal
  1. Ignition "OFF".
  2. Disconnect the electrical connector(s) from the concerned component.
MDPS ECU connector 1 (Memory Power) Chassis ground - Approx. 12V
  1. Ignition "OFF".
  2. Disconnect the electrical connector(s) from the concerned component.
  3. Ignition "ON".
MDPS ECU connector 1 (ON/START Input) Chassis ground - Approx. 12V
  1. Ignition "OFF".
  2. Disconnect the electrical connector(s) from the concerned component.
MDPS ECU connector 2 (ground) Chassis ground - Approx. below 1Ω

Good 

No Good