Ignition Systems: Distributor: Overhaul
WARNING:
The amplifier module is a sealed unit containing Beryllia. This substance is extremely dangerous if handled. Do not attempt to open or crush module.
- To disassemble, unclip and remove cap. Install a new cap if known to be faulty. Clean cap and high tension brush with a lint free cloth. Pull rotor arm from shaft. Install a new rotor arm if known to be faulty. Remove insulation cover (flash shield), secured by 3 screws. See Fig 1 . Install a new cover if known to be faulty.
- Remove 2 screws from vacuum unit securing bracket, disengage vacuum unit connecting rod from pick-up base plate connecting peg, and withdraw vacuum unit from distributor body. Remove 2 screws and withdraw module. Remove gasket.
- Remove 2 screws securing cast heatsink and remove heatsink. Use circlip pliers to remove circlip retaining reluctor on rotor shaft. Remove flat washer and then "O" ring recessed in top of reluctor.
- Gently withdraw reluctor from shaft, taking care not to damage teeth.NOTE: Coupling ring installed beneath reluctor.
- Remove 3 support pillars and cable grommet. Lift out pick-up and base plate assembly.NOTE: DO NOT disturb 2 barrel nuts securing pick-up module, otherwise air gap will need re-adjustment.
- Fit a new pick-up and base plate assembly if module is known to be faulty, otherwise check pick-up winding resistance (2000-5000 ohm).
- To reassemble, apply a spot of clean engine oil into rotor spindle before instating rotor arm. Apply Omnilube 2 (or equivalent) grease to auto advance mechanism, pick-up plate center bearing, pre tilt spring and its rubbing area (pick-up and base plate assembly), vacuum unit connecting peg (pick-up and base plate assembly), and connecting peg hole in vacuum unit connecting rod.
- Fit pick-up and base plate assembly. Pick-up leads must be prevented from fouling rotating reluctor. Both leads should be located in plastic guide as illustrated. See Fig 2 . Check during reassembly.
- Refit reluctor. Slide reluctor as far as it will go on rotor shaft, then rotate reluctor until it engages with coupling ring beneath pick-up base plate. Distributor shaft, coupling ring and reluctor are "keyed" and rotate together. Install "O" ring, flat washer and retaining circlip.
- Adjust pick-up air gap. Air gap between pick-up limb and reluctor teeth must be set within specified limits, using a non-ferrous feeler gauge.
- If adjustment is necessary, slacken 2 barrel nuts to set air gap. Air gap should be .008-.014" (.20-.35 mm). See Fig 3
.NOTE: When original pick-up and base plate assembly has been refitted air gap should be checked, and adjusted if necessary. When installing a new assembly, air gap will require adjusting to within specified limits.
- Before installing module, apply MS4 Silicone grease or equivalent heat-conducting compound to amplifier module backplate, seating face on distributor body and both faces of heatsink casting.