Oxygen Sensor Heater Resistance
Disconnect oxygen sensor connector. See COMPONENT LOCATIONS under INTRODUCTION. Measure resistance between terminals +B and HT of oxygen sensor connector. See Fig 1. Replace oxygen sensor if resistance is not as specified. See OXYGEN SENSOR HEATER RESISTANCE table.
OXYGEN SENSOR HEATER RESISTANCE
| Application | (1) Ohms | ||
|---|---|---|---|
| LS400 | 5.1-6.3 | ||
|
|||