Oxygen Sensor Heater Resistance

Disconnect oxygen sensor connector. See COMPONENT LOCATIONS  under INTRODUCTION. Measure resistance between terminals +B and HT of oxygen sensor connector. See Fig 1. Replace oxygen sensor if resistance is not as specified. See OXYGEN SENSOR HEATER RESISTANCE  table.

OXYGEN SENSOR HEATER RESISTANCE

Application (1) Ohms
LS400 5.1-6.3
(1) At 68°F (20°C).
Fig 1: Measuring Resistance Of Oxygen Sensor Heater (LS400)
G93I78194Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002