Control Relay Circuit

Turn ignition off. Disconnect sun roof control relay harness connector. Measure voltage or continuity between specified control relay harness connector terminals under specified conditions. See CONTROL RELAY CIRCUIT TEST  table. See Fig 1. If test results are as specified, replace control relay. If test results are not as specified, repair or replace appropriate switch or wire. See WIRING DIAGRAMS .

CONTROL RELAY CIRCUIT TEST

Measure Between Ground & Terminal No. Condition Specification
2 Sun Roof Switch Released No Continuity
2 Sun Roof Switch In TILT UP Or SLIDE CLOSE position Continuity
3 Ignition Switch In OFF Or ACC Position (1) No Voltage
3 Ignition Switch In ON Position Battery Voltage
4 Constant Battery Voltage
5 Sun Roof Switch Released No Continuity
5 Sun Roof Switch In TILT UP Or SLIDE CLOSE position Continuity
7 Constant Continuity
8 Constant Continuity
10 Constant Continuity
(1) Except during 60 seconds after ignition is turned off (unless door is opened).
Fig 1: Identifying Control Relay Harness Connector Terminals
G93E84875Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002