Pressure Sensor: Removal
- Discharge refrigerant from refrigeration systemNOTE: At the time of installation, please refer to the following items:
- Evacuate air from refrigeration system.
- Charge system with refrigerant and inspect for leakage of refrigerant.
- Specified amount:
- Single A/C: 650 +/- 50g (22.93 +/- 1.76 oz.)
- Dual A/C: 900 +/- 50g (31.74 +/- 1.76 oz.)
- Specified amount:
- Remove pressure switch.
- Disconnect the connector.
- Remove the pressure switch from the liquid tube.
Torque: 10 N.m (100kgf.cm, 7 ft.lbf)
NOTE:- Lock the switch mount on the tube with an open end wrench, being careful not to deform the tube, and remove the switch.
- At the time of installation, please refer to the following item:
Lubricate a new O-ring with compressor oil and install them to the switch.