FixVault

Flex Lock-Up Speed Specifications

FLEX LOCK-UP SPEED SPECIFICATIONS (GS 300)

Application MPH
"D" Range (1)
When Accelerating
Lock-Up On In 5th 24-27
Lock-Up Off In 5th 24-27
Lock-Up On In 4th 19-21
Lock-Up Off In 4th 17-19
"4" Range (1)
Lock-Up On In 4th 24-27
Lock-Up Off In 4th 23-26
"D" Range (2)
When Decelerating (A/C On)
Lock-Up On In 5th 58-63
Lock-Up Off In 5th 20-33
"4" Range (2)
When Decelerating (A/C On)
Lock-Up On In 4th 58-63
Lock-Up Off In 4th 15-25
"D" Range (2)
When Decelerating (A/C Off)
Lock-Up On In 5th 58-63
Lock-Up Off In 5th 20-23
"4" Range (2)
When Decelerating (A/C Off)
Lock-Up Off In 4th 13-17
(1) Throttle valve opened 3 percent.
(2) Throttle valve fully closed.
FLEX LOCK-UP SPEED SPECIFICATIONS (GS 430)

Application MPH
"D" Range (1)
When Accelerating
Lock-Up On In 5th 29-33
Lock-Up Off In 5th 28-32
"4" Range (1)
When Accelerating
Lock-Up On In 4th 22-25
Lock-Up Off In 4th 21-24
"3" Range (1)
When Accelerating
Lock-Up On In 3rd 16-19
Lock-Up Off In 3rd 14-17
(1) Throttle valve opened 3 percent.
FLEX LOCK-UP SPEED SPECIFICATIONS (IS 300)

Application MPH
"D" Range (1)
When Accelerating
Lock-Up On In 5th 23-27
Lock-Up Off In 5th 22-25
"4" Range
When Accelerating
Lock-Up On In 4th 17-32
Lock-Up Off In 4th 18-20
(1) Throttle valve opened 3 percent.
FLEX LOCK-UP SPEED SPECIFICATIONS (SC 430)

Application MPH
"D" Range (1)
When Accelerating
Lock-Up On In 5th 29-33
Lock-Up Off In 5th 28-32
"4" Range (1)
When Accelerating
Lock-Up On In 4th 22-25
Lock-Up Off In 4th 21-24
"3" Range (1)
When Accelerating
Lock-Up On In 3rd 16-19
Lock-Up Off In 3rd 14-17
(1) Throttle valve opened 3 percent.