Inspect Defogger Timer Operation
- Connect the positive (+) lead from the voltmeter to terminal 6 of body ECU No. 1 connector and negative (-) lead to body ground.
- When the switch is OFF, the voltage should be approx. 12V.
- Turn the defogger switch ON and check that the indicator lights up and that the voltage is less than 1 V.
- After 15 minutes, check that the switch is OFF and the voltage is approx. 12 V.
If operation is not as specified, replace the switch.