FixVault

Service Data

STARTER COMPONENTS SERVICE DATA SPECIFICATIONS (3UZ-FE)

Starter Rated voltage and output power 12 V 2.0 kW
No-load characteristics Current
rpm
100 A or less at 11.5 V
2,500 rpm or less
Brush length STD
Minimum
15.0 mm (0.591 in.)
9.0 mm (0.354 in.)
Spring installed load STD
Minimum
21.5 - 27.5 N (2.2 - 2.8 kgf, 4.9 - 6.2 lbf)
12.7 N (1.3 kgf, 2.9 lbf)
Commutator
Diamiter STD
Minimum
35.0 mm (1.378 in.)
34.0 mm (1.339 in.)
Undercut depth STD
Minimum
0.7 mm (0.028 in.)
0.2 mm (0.008 in.)
Circle runout Maximum 0.05 mm (0.0020 in.)
Magnetic switch    
Contact plate for wear Maximum 0.9 mm (0.035 in.)