FixVault

Manual Operation (Driver's Window)

When the power window master switch is operated to UP position with the ignition on, the current flows from the D FR P/W fuse to the power window master switch TERMINAL 1 to TERMINAL 8 to the front LH power window motor TERMINAL 1 to TERMINAL 2 to the power window master switch TERMINAL 20 to TERMINAL 9 to GROUND, and the motor rotates to close the window.

When the power window master switch is operated DOWN position with the ignition on, the current flows from the D FR P/W fuse to the power window master switch TERMINAL 1 to TERMINAL 20 to the front LH power window motor TERMINAL 2 to TERMINAL 1 to the power window master switch TERMINAL 8 to TERMINAL 9 to GROUND, and the motor rotates to open the window.