FixVault

Service Data

COOLING SYSTEM COMPONENTS SERVICE SPECIFICATION

Thermostat Valve opening temperature 80 - 84°C (176 - 183°F)
Valve lift : At 95°C (203°F) 10 mm (0.39 in.) or more
Radiator cap Relief valve opening pressure :
  1. STD
  2. Minimum
  1. 93 - 123 kPa (095 - 1.25 kgf/cm2 , 13.5 - 17.8 psi)
  2. 78 kPa (0.8 kgf/cm2 , 11.4 psi)
Electric cooling fan 100W model Voltage : 1 - 3 9 - 14 V