| Thermostat | |
| Valve opening temperature | 80 to 84°C (176 to 183°F) |
| Valve lift at 95°C (203°F) | 10 mm (0.39 in.) or more |
| Water outlet cap sub-assy | |
| Standard opening pressure | 83 to 113 kPa (0.85 to 1.15 kgf/cm2 , 12.1 to 16.4 psi) |
| Minimum opening pressure | 69 kPa (0.7 kgf/cm2 , 10.0 psi) |
| Cooling fan | |
| Standard amperage at 20°C (68°F) | 10.2 to 16.2 A |