FixVault

Transmission Wire: Notes

CAUTION: When working with FIPG material, you must observe the following items:
  • Using a razor blade and gasket scraper, remove all the old, FIPG material from the gasket surfaces.
  • Thoroughly clean all components to remove all the loose material.
  • Clean both sealing surfaces with a non-remove solvent.
  • Apply FIPG in an approx. 0.04 in. (1 mm) wide bead along the sealing surface.
  • Parts must be assembled within 10 minutes of application. Otherwise, the FIPG material must be removed and reapplied.