Inspection Procedure
- INSPECT FUSE (ECU-B, GAUGE1, IG2)
- Check the continuity in ECU-B fuse.
- Check the continuity in GAUGE1 fuse.
- Check the continuity in IG2 fuse.
NG: REPLACE FUSE
OK: Go To Next Step
- CHECK COMBINATION METER ASSY (POWER SOURCE CIRCUIT)
- Check voltage.
- Remove the combination meter assy with connectors still connected.
- Measure voltage between terminal C7-20 of combination meter assy connector and body ground.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- Voltage: 10 - 14 V
- Turn the ignition switch to ON.
- Measure voltage between terminal C7-39 of combination meter assy connector and body ground.
- Voltage: 10 - 14 V
- Turn the ignition switch to ON.
- Measure voltage between terminal C7-40 of combination meter assy connector and body ground.
- Voltage: 10 - 14 V
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go To Next Step
- Check voltage.
- CHECK COMBINATION METER ASSY (GROUND CIRCUIT)
- Check continuity.
- Disconnect the "C7" connector from combination meter assy.
- Check continuity between terminal C7-1 of combination meter assy connector and body ground.
- OK: Continuity exists
- Check continuity between terminal C7-21 of combination meter assy connector and body ground.
- OK: Continuity exists
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go To Next Step
CHECK AND REPLACE COMBINATION METER ASSY
- Check continuity.