FixVault

Inspection Procedure

  1. INSPECT FUSE (ECU-B, GAUGE1, IG2) 
    1. Check the continuity in ECU-B fuse.
    2. Check the continuity in GAUGE1 fuse.
    3. Check the continuity in IG2 fuse.

    NG: REPLACE FUSE 

    OK: Go To Next Step 

  2. CHECK COMBINATION METER ASSY (POWER SOURCE CIRCUIT) 
    1. Check voltage.
      1. Remove the combination meter assy with connectors still connected.
      2. Measure voltage between terminal C7-20 of combination meter assy connector and body ground.
        Fig 1: Checking Combination Meter Assy Connector Terminals (Power Source Circuit)
        G02938750Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
        1. Voltage: 10 - 14 V 
      3. Turn the ignition switch to ON.
      4. Measure voltage between terminal C7-39 of combination meter assy connector and body ground.
        1. Voltage: 10 - 14 V 
      5. Turn the ignition switch to ON.
      6. Measure voltage between terminal C7-40 of combination meter assy connector and body ground.
        1. Voltage: 10 - 14 V 

    NG: REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: Go To Next Step 

  3. CHECK COMBINATION METER ASSY (GROUND CIRCUIT) 
    1. Check continuity.
      1. Disconnect the "C7" connector from combination meter assy.
      2. Check continuity between terminal C7-1 of combination meter assy connector and body ground.
        1. OK: Continuity exists 
      3. Check continuity between terminal C7-21 of combination meter assy connector and body ground.
        Fig 2: Checking Combination Meter Assy Connector Terminals (Ground Circuit)
        G02938751Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      1. OK: Continuity exists 

    NG: REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: Go To Next Step 

    CHECK AND REPLACE COMBINATION METER ASSY