Lighting System: Inspection
- HEADLAMP DIMMER SWITCH ASSY
- Inspect the light control switch continuity.
- Check continuity between terminals at each switch position as shown in LIGHT CONTROL SWITCH CONTINUITY .LIGHT CONTROL SWITCH CONTINUITY
Switch operation Tester connection Specified condition OFF - No continuity TAIL 14 - 16 Continuity HEAD 13 - 16 - 14 Continuity AUTO 16 - 12 Continuity
- Check continuity between terminals at each switch position as shown in LIGHT CONTROL SWITCH CONTINUITY .
- Inspect the headlamp dimmer switch continuity.
- Check continuity between terminals at each switch position as shown in HEADLAMP DIMMER SWITCH CONTINUITY .HEADLAMP DIMMER SWITCH CONTINUITY
Switch operation Tester connection Specified condition FLASH 7 - 8 - 16 Continuity LOW BEAM 16 - 17 Continuity HI BEAM 7 - 16 Continuity
- Check continuity between terminals at each switch position as shown in HEADLAMP DIMMER SWITCH CONTINUITY .
- Inspect the turn signal switch continuity.
- Check continuity between terminals at each switch position as shown in TURN SIGNAL SWITCH CONTINUITY .TURN SIGNAL SWITCH CONTINUITY
Switch operation Tester connection Specified condition Right turn 2 - 3 Continuity Neutral - No continuity Left turn 1 - 2 Continuity
- Check continuity between terminals at each switch position as shown in TURN SIGNAL SWITCH CONTINUITY .
- Inspect the front fog lamp switch continuity.
- Check continuity between terminals at each switch position as shown in FRONT FOG LAMP SWITCH CONTINUITY .FRONT FOG LAMP SWITCH CONTINUITY
Switch operation Tester connection Specified condition OFF - No continuity ON 10 - 11 Continuity
- Check continuity between terminals at each switch position as shown in FRONT FOG LAMP SWITCH CONTINUITY .
- Inspect the light control switch continuity.
- HAZARD WARNING SIGNAL SWITCH ASSY
- Check continuity between terminals at each switch position as shown in WARNING SIGNAL SWITCH ASSY .WARNING SIGNAL SWITCH ASSY
Switch operation Tester connection Specified condition OFF 2 - 3 No continuity ON 2 - 3 Continuity Illumination circuit 4 - 5 Continuity - Inspect illumination operation.
- Connect the battery positive (+) lead to terminal 4 and the battery negative (-) lead to terminal 5, then check that the illumination comes on.
- Check continuity between terminals at each switch position as shown in WARNING SIGNAL SWITCH ASSY .
- FRONT DOOR COURTESY LAMP SWITCH ASSY
- Inspect courtesy lamp assy continuity.
- Check continuity between terminals when the switch is operated.
Standard:
- ON (When shaft is pressed): No continuity
- OFF (When shaft is not pressed): Continuity
- Check continuity between terminals when the switch is operated.
- Inspect courtesy lamp assy continuity.
- REAR DOOR COURTESY LAMP SWITCH ASSY
- Inspect courtesy lamp assy continuity.
- Check continuity between terminal and the switch body when the switch is operated.
Standard:
- ON (When shaft is pressed): No continuity
- OFF (When shaft is not pressed): Continuity
- Check continuity between terminal and the switch body when the switch is operated.
- Inspect courtesy lamp assy continuity.
- BACK DOOR COURTESY LAMP SWITCH ASSY
- Inspect courtesy lamp assy continuity.
- Check continuity between terminal and the switch body when the switch is operated.
Standard:
- ON (When shaft is pressed): No continuity
- OFF (When shaft is not pressed): Continuity
- Check continuity between terminal and the switch body when the switch is operated.
- Inspect courtesy lamp assy continuity.
- GLOVE BOX LAMP SWITCH
- Inspect courtesy lamp assy continuity.
- Check continuity between terminals when the switch is operated.
Standard:
- ON (When shaft is pressed): No continuity
- OFF (When shaft is not pressed): Continuity
- Check continuity between terminals when the switch is operated.
- Inspect courtesy lamp assy continuity.
- HEADLAMP RELAY
- TAIL LAMP RELAY
- FOG LAMP RELAY
- ROOM LAMP CONTROL RELAY (DOME RELAY)
- PARK/NEUTRAL POSITION SWITCH RELAY (BK/UP RELAY)
- TOWING CONVERTER RELAY (BATT CHG RELAY)
- TOWING CONVERTER RELAY (TOWING TAIL RELAY)
- TRANSPONDER KEY AMPLIFIER
- Connect the battery positive (+) lead to terminal 2 and the battery negative (-) lead to terminal 6, and check that the indicator light comes on.
- MAP LAMP ASSY
- Inspect map light assy continuity.
- Check continuity between terminals at each switch position as shown in MAP LAMP ASSY .
Standard:
MAP LAMP ASSYSwitch operation Tester connection Specified condition OFF - No continuity DOOR 7 (+B) - 2 (DOOR) Continuity ON 7 (+B) - 4 (E) Continuity
- Check continuity between terminals at each switch position as shown in MAP LAMP ASSY .
- Inspect map light assy continuity.
- ROOM LAMP ASSY NO. 1
- Inspect room lamp assy No. 1 continuity.
- Check continuity between terminals at each switch position as shown in TESTER CONNECTION AND SPECIFIED CONDITION .
Standard:
ROOM LAMP ASSY NO. 1Switch operation Tester connection Specified condition OFF - No continuity DOOR 1 - 2 Continuity ON 1 - 3 Continuity
- Check continuity between terminals at each switch position as shown in TESTER CONNECTION AND SPECIFIED CONDITION .
- Inspect room lamp assy No. 1 continuity.
- ROOM LAMP ASSY NO. 2
- Inspect room lamp assy No. 2 continuity.
- Check continuity between terminals at each switch position as shown in ROOM LAMP ASSY NO. 2 .
Standard:
ROOM LAMP ASSY NO. 2Switch operation Tester connection Specified condition OFF - No continuity DOOR 1 - 2 Continuity ON 1 - 3 Continuity
- Check continuity between terminals at each switch position as shown in ROOM LAMP ASSY NO. 2 .
- Inspect room lamp assy No. 2 continuity.
- FRONT DOOR COURTESY LAMP ASSY RH
- Check continuity between terminals.
Standard: Continuity exists
- Check continuity between terminals.
- FRONT DOOR COURTESY LAMP ASSY LH
- Check continuity between terminals.
Standard: Continuity exists
- Check continuity between terminals.
- GLOVE BOX LAMP ASSY
- Check continuity between terminals.
Standard: Continuity exists
- Check continuity between terminals.
- RH VISOR ASSY
- Inspect vanity light continuity.
- Check continuity between terminals 1 and 2 when the light is operated.
Standard:
- OFF (closed): No continuity
- ON (opened): Continuity
- Check continuity between terminals 1 and 2 when the light is operated.
- Inspect vanity light continuity.
- LH VISOR ASSY
- Inspect vanity light continuity.
- Check continuity between terminals 1 and 2 when the light is operated.
Standard:
- OFF (closed): No continuity
- ON (opened): Continuity
- Check continuity between terminals 1 and 2 when the light is operated.
- Inspect vanity light continuity.
- STOP LAMP SWITCH ASSY
- Check continuity between terminals at each switch position as shown in STOP LAMP SWITCH ASSY .
Standard:
STOP LAMP SWITCH ASSYSwitch position Tester connection Specified condition Switch pin free 1 - 2 No continuity Switch pin free 3 - 4 Continuity Switch pin pushed in 1 - 2 Continuity Switch pin pushed in 3 - 4 No continuity
- Check continuity between terminals at each switch position as shown in STOP LAMP SWITCH ASSY .
- LAMP ASSY, INTERIOR ILLUMINATION, NO. 1
(Inside Handle Illumination)
- Check continuity between terminals 1 (+B) and 2 (GND).
Standard: Continuity
HINT:
Connect the positive (+) terminal of the tester to the terminal 1 (+B) of the connector, and the negative (-) terminal of the tester to the terminal 2 (GND) of the connector to check the continuity.
- Check continuity between terminals 1 (+B) and 2 (GND).
- INTERIOR ILLUMINATION LAMP ASSY NO. 2
(Driver Side Foot Light)
- Check continuity between terminals 1 (+B) and 2 (GND).
Standard: Continuity
HINT:
Connect the positive (+) terminal of the tester to the terminal 1 (+B) of the connector, and the negative (-) terminal of the tester to the terminal 2 (GND) of the connector to check the continuity.
- Check continuity between terminals 1 (+B) and 2 (GND).
- INTERIOR ILLUMINATION LAMP ASSY NO. 2
(Front Passenger Side Foot Light)
- Check continuity between terminals 1 (+B) and 2 (GND).
Standard: Continuity
HINT:
Connect the positive (+) terminal of the tester to the terminal 1 (+B) of the connector, and the negative (-) terminal of the tester to the terminal 2 (GND) of the connector to check the continuity.
- Check continuity between terminals 1 (+B) and 2 (GND).
- STEP LAMP ASSY (RH Side)
- Inspect the side step lamp assy.
- Check continuity between terminals when the courtesy lamp switch is operated.
Standard:
ON: Continuity
OFF: No continuity
- Inspect the side step lamp assy.
- STEP LAMP ASSY (LH Side)
- Check continuity between terminals when the courtesy lamp switch is operated.
Standard:
ON: Continuity
OFF: No continuity