Refrigerant Line: Replacement
- DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM
- REPLACE FAULTY TUBE OR HOSE NOTE: Cap the open fittings immediately to keep moisture or dirt out of the system.
- TIGHTEN JOINT OF BOLT OR NUT TO SPECIFIED TORQUE NOTE: Do not tighten the connections more than specified.REFRIGERANT LINE TORQUE SPECIFICATIONS
Part tightened N.m kgf.cm ft.lbf Compressor x Discharge hose 10 100 7 Compressor x Suction hose 10 100 7 Condenser x Discharge hose 10 10 7 Condenser x Liquid tube 10 100 7 Rear cooling unit x Liquid and suction tubes 10 100 7 Liquid line Nut 14 140 10 Liquid line Bolt 10 100 7 Discharge line Nut 22 225 16 Suction line Nut 32 330 24 Suction line Bolt 10 100 7 - EVACUATE AIR FROM REFRIGERATION SYSTEM AND CHARGE SYSTEM WITH REFRIGERANT
Specified amount: 1,050 +/- 50 g (37.03 +/- 1.76 oz.)
- INSPECT FOR LEAKAGE OF REFRIGERANT
Using a gas leak detector, check for leaks of refrigerant
- INSPECT AIR CONDITIONING OPERATION