FixVault

Typical Malfunction Thresholds

TYPICAL MALFUNCTION THRESHOLDS

Either of the following conditions is met: Condition 1 or 2
1. Frequency that both of the following conditions (a) and (b) are met: 5 times or more
(a) Engine RPM - target engine RPM Less than -100 rpm or more than 150 rpm
(b) Vehicle condition Stop after vehicle was driven by 10 km/h (6.25 mph) or more
2. Frequency that both of the following conditions (a) and (b) are met: Once
(a) Engine RPM - target engine RPM Less than -100 rpm or more than 150 rpm
(b) Intake air control flow rate learning value 2.48 L/sec. or less, or 11 L/sec. or more