FixVault

Typical Malfunction Thresholds

TYPICAL MALFUNCTION THRESHOLDS

Either of the following conditions is met: Condition 1 or 2
1. Frequency that both of the following conditions (a) and (b) are met: 5 times or more
(a) Engine RPM - Target engine RPM Less than -100 rpm, or more than 150 rpm
(b) Vehicle condition Stop after vehicle was driven at 6.25 mph (10 km/h) or more
2. Frequency that both of the following conditions (a) and (b) are met: Once
(a) Engine RPM - Target engine RPM Less than -100 rpm, or more than 150 rpm
(b) IAC flow rate learning value 1.3 L/sec. or less, or 9.03 L/sec. or more