Inspection Procedure
- INSPECT COMBINATION METER ASSEMBLY
- Disconnect the E19 connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition E19-12 (E2) - Body ground Always Below 1 Ω E19-24 (ES) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard voltage
VOLTAGE SPECIFICATIONTester Connection Condition Specified Condition E19-13 (IG+) - Body ground Turn the engine switch on (IG) 10 to 14 V E19-1 (B2) - Body ground Always 10 to 14 V E19-2 (B) - Body ground Always 10 to 14 V
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: REPLACE COMBINATION METER ASSEMBLY