Inspection Procedure
- INSPECT FUSE (A/C)
- Remove the A/C fuse from the instrument panel J/B.
- Measure the resistance according to the value (s) in the table below.
Standard resistance
FUSE (A/C) RESISTANCETester Item Condition Specified Condition A/C fuse Always Below 1 Ω
NG: REPLACE FUSE (A/C)
OK: Go to Next Step
- INSPECT AIR CONDITIONING AMPLIFIER (AIR CONDITIONING AMPLIFIER - BODY GROUND)
- Disconnect the A/C amplifier connector.
- Measure the voltage according to the value (s) in the table below.
Standard voltage
AIR CONDITIONING AMPLIFIER (AIR CONDITIONING AMPLIFIER - BODY GROUND) VOLTAGETester Connection Condition Specified Condition E1-21 (B) - Body ground Always 10 to 14 V
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE