Customize Parameters
HINT:
The following items can be customized.
NOTE:
- When the customer requests a change in a function, first make sure that the function can be customized.
- Be sure to make a note of the current settings before customizing.
- When troubleshooting a function, first make sure that the function is set to the default setting.
AIR CONDITIONER:
AIR CONDITIONER CUSTOMIZE PARAMETERS
| DISPLAY (ITEM) | DEFAULT | CONTENTS | SETTING |
|---|---|---|---|
| SET TEMP SHIFT (Set Temperature Shift) | NORMAL | To shift the temperature against the displayed temperature | +2 C / +1 C / NORMAL 1 AC 1-2 C |
| AIR INLET MODE (Air Inlet Mode) | AUTO | In case of turning the A/C ON when you desire to make the compartment cool down quickly, this is the function to change the mode automatically to RECIRCULATION mode | MANUAL/AUTO |
| COMPRESSOR MODE (Compressor Mode) | AUTO | Function to turn the A/C ON automatically by pressing the AUTO button when the blower is ON and the A/C is OFF | MANUAL/AUTO |
| COMPRS / DEF OPER (Compressor / Air Inlet DEF Operation) | LINK | Function to turn the A/C ON automatically linked with the FRONT DEF button when the A/C is OFF | NORMAL/LINK |
| EVAP CTRL (Evaporator Control) | AUTO | Function to set the evaporator control to the AUTOMATIC position (AUTO) to save power, or to the coldest position (MANUAL) to dehumidify the air and to prevent the windows from fogging up | MANUAL/AUTO |
| GAS SENS SHIF (Emission Gas Sensor Shift) | NORMAL | Function to change the sensitivity of the exhaust gas sensor | MU MORE / MORE / LI MORE / NORMAL / LI LESS / LESS / MU LESS |
| BUTTON PRS BUZ | ON | Function to sound a buzzer when a button is pressed | OFF/ON |
| FOOT/DEF MODE (Foot / DEF Auto Mode) | ON | Function to turn the airflow from FOOT/DEF ON automatically when AUTO MODE is ON | OFF/ON |
| AUTO BLOW UP (Foot / DEF Automatic Blower Up Function) | ON | Function to change the blower level automatically when the defroster is ON | OFF/ON |
| AMBIENT TMP SFT (Ambient Temperature Shift) | NORMAL | Function to shift the ambient temperature against the displayed ambient temperature | +3C / +2C/+1 C / NORMAL /-1 C / -2 C / -3 C |