Inspection Procedure
- CHECK HARNESS AND CONNECTOR (IG+, B - BODY GROUND)
- Disconnect the connector from the A/C control assembly.
- Measure the voltage according to the value (s) in the table below.
Standard voltage
IG+, B - BODY GROUNDTester Connection (Symbols) Condition Specified Condition E3-2 (IG+) - Body ground Engine switch on (IG) 10 to 14 V E3-2 (IG+) - Body ground Engine switch off Below 1 V E3-1 (+B) - Body ground Always 10 to 14 V
NG: GO TO SMART ACCESS SYSTEM WITH PUSH-BUTTON START (See HOW TO PROCEED WITH TROUBLESHOOTING )
OK: Go to Next Step
- CHECK HARNESS AND CONNECTOR (GND - BODY GROUND)
- Measure the resistance according to the value (s) in the table below.
Standard resistance
GND - BODY GROUNDTester Connection (Symbols) Condition Specified Condition E3-18 (GND) - Body ground Always Below 1 Ω
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE