FixVault

Typical Enabling Conditions

TYPICAL ENABLING CONDITIONS

Engine Running
Transmission counter gear revolution 300 rpm or more
Battery voltage 8 V or more
Engine switch ON
Starter OFF
Either a or b is met (See below)  
a. All of the following conditions are met  
ECT 20°C (68°F) or more
ECT sensor fail Not detected
Time after PNP switch ON to OFF 2 sec. or more
b. All of the following conditions are met  
CT Less than 20°C (68°F)
ECT sensor fail Detected
Time after PNP switch ON to OFF 30 sec. or more