Room Temperature Sensor: Inspection

  1. INSPECT ROOM TEMPERATURE SENSOR 
    1. Remove the A/C room temperature sensor.
    2. Disconnect the connector from the A/C room temperature sensor.
    3. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      TESTER CONNECTION SPECIFIED CONDITION

      Tester Connection Condition Specified Condition
      1 (+) - 2 (-) 10°C (50°F) 3.00 to 3.73 kΩ
      1 (+) - 2 (-) 15°C (59°F) 2.45 to 2.88 kΩ
      1 (+) - 2 (-) 20°C (68°F) 1.95 to 2.30 kΩ
      1 (+) - 2 (-) 25°C (77°F) 1.60 to 1.80 kΩ
      1 (+) - 2 (-) 30°C (86°F) 1.28 to 1.47 kΩ
      1 (+) - 2 (-) 35°C (95°F) 1.00 to 1.22 kΩ
      1 (+) - 2 (-) 40°C (104°F) 0.80 to 1.00 kΩ
      1 (+) - 2 (-) 45°C (113°F) 0.65 to 0.85 kΩ
      1 (+) - 2 (-) 50°C (122°F) 0.50 to 0.70 kΩ
      1 (+) - 2 (-) 55°C (131°F) 0.44 to 0.60 kΩ
      1 (+) - 2 (-) 60°C (140°F) 0.36 to 0.50 kΩ
      Fig 1: Room Temperature Sensor Graph
      G05297963Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      NOTE:
      • Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
      • When measuring, the sensor temperature must be the same as the ambient temperature.

      HINT:

      As the temperature increases, the resistance decreases (see the graph).