FixVault

Typical Enabling Conditions

System monitor: 

TYPICAL ENABLING CONDITIONS

Time after engine start 10 seconds or more
Time after fuel cut finished 3 seconds or more
Target fuel pressure Small change

Closed stuck: 

TYPICAL ENABLING CONDITIONS

Fuel relief valve Activation
Injector driver malfunction Not detected
Fuel pressure sensor malfunction Not detected
High pressure fuel pump malfunction Not detected
Fuel pressure before opening valve 3 MPa or more
Maintenance mode OFF
Fuel relief valve during current driving cycle Not monitoring