FixVault

Absorber Control Switch: Inspection

  1. INSPECT ABSORBER CONTROL SWITCH 
    1. Measure the resistance of the switch.

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Switch Condition Specified Condition
      4 - 3 NORM 10 kΩ or higher
      4 - 3 SPORT Below 1 Ω
      Fig 1: Identifying Absorber Control Switch Connector Terminals
      G05296564Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002