Lumbar Support Adjuster Assembly: Inspection
- INSPECT LUMBAR SUPPORT ADJUSTER ASSEMBLY
- Inspect operation of the motor.
Standard
LUMBAR SUPPORT ADJUSTER MOTOR SPECIFICATIONTester Condition Operational Direction Battery positive voltage → 1
Battery negative voltage → 2Clockwise Battery positive voltage → 2
Battery negative voltage → 1Counterclockwise If the result is not as specified, replace the lumbar support adjuster motor.