FOOTWELL Light: Inspection
- INSPECT FOOTWELL LIGHT
- Disconnect the connector from the footwell light.
- Measure the voltage according to the value (s) in the tables below.
Standard voltage LH Side:
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition J19-2-J19-1 Doors are unlocked by the transmitter 10 to 14 V J19-2-J19-1 All doors are closed Below 1 V RH Side:
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition J60-2 - J60-1 Doors are unlocked by the transmitter 10 to 14 V J60-2 - J60-1 All doors are closed Below 1 V Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
If the result is not as specified, repair or replace the wire harness or connector.
- Connect the (+) lead from the battery to terminal 2 and the (-) lead to terminal 1.
- Check that the footwell light comes on.
OK: Comes on
If the result is not as specified, replace the footwell light.