FixVault

Inspection Procedure

  1. CHECK ECM (FPR VOLTAGE) 
    1. Measure the voltage of the ECM connectors.

      Standard voltage 

      VOLTAGE SPECIFICATION

      Tester Connection Condition Specified Condition
      E6-30 (FPR) - E6-1 (E1) STA signal ON 9 to 14 V
      E6-30 (FPR) - E6-1 (E1) STA signal OFF 0 to 3V

    NG: REPLACE ECM 

    Fig 1: Identifying ECM Connector Terminals
    G05282235Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    OK: Go to next step 

  2. INSPECT FUEL PUMP RELAY (Marking: F/PUMP) 
    1. Remove the fuel pump relay from the engine room relay block.
    2. Measure the resistance of the fuel pump relay.

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Specified Condition
      3 - 4 Below 1 Ω
      3 - 5 10 kΩ or higher
      3 - 4 10 kΩ or higher (when battery voltage is applied to terminals 1 and 2)
      3 - 5 Below 1 Ω (when battery voltage is applied to terminals 1 and 2)

    NG: REPLACE FUEL PUMP RELAY 

    Fig 2: Identifying Fuel Pump Relay Connector Terminals
    G04829434Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    OK: Go to next step 

  3. CHECK HARNESS AND CONNECTOR (FUEL PUMP RELAY - ECM) 
    1. Check harness and connector (see ELECTRONIC CIRCUIT INSPECTION PROCEDURE ).

    NG: REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: REPLACE ECM