FixVault

Typical Malfunction Thresholds

TYPICAL MALFUNCTION THRESHOLDS

1. Frequency that both of following conditions (a) and (b) are met 5 times or more
(a) Engine RPM - Target engine RPM (A/C OFF and NSW OFF) Less than -100 rpm, or more than 150 rpm
(b) Vehicle condition Stop after vehicle was driven at 10 km/h (6 mph) or more
2. Frequency that both of following conditions (a) and (b) are met Once
(a) Engine RPM - Target engine RPM (A/C OFF and NSW OFF) Less than -100 rpm, or more than 150 rpm
(b) IAC flow rate learning value 2.48 L/sec or less, or 11 L/sec