FixVault

Damping Force Control Actuator: Inspection

  1. INSPECT DAMPING FORCE CONTROL ACTUATOR 
    1. Disconnect the damping force control actuator connector.
    2. Measure resistance between each terminal of damping force control actuator.

    Standard resistance 

    RESISTANCE SPECIFIED CONDITIONS

    Terminals No. Specified Condition
    Terminals 1 and 2 12.0 to 13.6 Ω
    Terminals 2 and 3 12.0 to 13.6 Ω
    Terminals 2 and 4 12.0 to 13.6 Ω
    Terminals 2 and 5 12.0 to 13.6 Ω
    Fig 1: Measuring Resistance Between Each Terminal Of Damping Force Control Actuator
    G04063633Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002