FixVault

Height Control Accumulator: Disposal

  1. DISPOSE OF HEIGHT CONTROL ACCUMULATOR ASSEMBLY 
    1. Place the accumulator in a vise and saw a hole between "A" and "B" shown in the illustration using a saw to discharge the gas inside.
    CAUTION:
    • Before the gas discharging, loosen the bleeder plug to bleed high pressure oil.
    • The gas discharging is colorless, odorless and harmless.
    • Saw a hole while covering the saw with a cloth because chips may fly up.
    Fig 1: Identifying Measurements For Sawing Hole
    G04063625Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002