FixVault

Wireless Door Lock Control System: Precaution

  1. GENERAL PRECAUTION 
    1. While using the battery during inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
  2. PRECAUTION FOR DISCONNECTING THE BATTERY CABLE 
    NOTE: When disconnecting the negative (-) battery terminal, initialize the following systems after the terminal is reconnected.
    SYSTEM REFERENCE TABLE

    System Name Information
    Lighting System INITIALIZATION
    Power Door Lock Control System INITIALIZATION
    Power Window Control System INITIALIZATION
    Power Back Door System INITIALIZATION
    Sliding Roof System (for Multi-panel Moon Roof) INITIALIZATION
    Sliding Roof System (for Standard) INITIALIZATION