Integration Control And Panel: Inspection
- INSPECT INTEGRATION CONTROL AND PANEL ASSEMBLY
- Check the blower switch resistance.
- Using an ohmmeter, measure the resistance and check the results in accordance with the values in the table below.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITIONTester connection Blower Switch Position Specified Condition 1 - 4 - 5 - 6 - 8 OFF 10 KΩ or higher 1 - 8 LO Below 1 Ω 1 - 6 - 8 M1 Below 1 Ω 1 - 5 - 8 M2 Below 1 Ω 1 - 4 - 8 HI Below 1 Ω If the result is not as specified, replace the integration control and panel assembly.
- Using an ohmmeter, measure the resistance and check the results in accordance with the values in the table below.
- Inspect the illumination operation.
- Connect the positive (+) lead from the battery to terminals 1 (IG+) and 2 (ILL+) and the negative (-) lead to terminal 20 (GND), then check that the illuminations light up.
Standard:
Illuminations light up
If the result is not as specified, replace the integration control and panel assembly.
- Connect the positive (+) lead from the battery to terminals 1 (IG+) and 2 (ILL+) and the negative (-) lead to terminal 20 (GND), then check that the illuminations light up.
- Inspect the A/C indicator operation.
- Connect the positive (+) lead from the battery to terminal 1 (IG+) and the negative (-) lead to terminals 8 (BLW) and 20 (GND).
- Push the A/C button in and then check that the indicator lights up.
Standard
SWITCH CONDITIONSwitch Condition Specified Condition Switch ON Indicator illuminates Switch OFF Indicator turns off HINT:
Inspect the A/C indicator operation in any position except MAX COOL. The A/C indicator ON/OFF operation does not function in MAX COOL position (The A/C indicator is held in ON state).
If the result is not as specified, replace the integration control and panel assembly.
- Under the above condition, connect the positive (+) lead from the battery to terminal 2 (ILL+) and then check that the indicator dims.
Standard
SWITCH CONDITIONSwitch Condition Specified Condition Switch ON Indicator dims Switch OFF Indicator turns off HINT:
Inspect the A/G indicator operation in any position except MAX COOL. The A/C indicator ON/OFF operation does not function in MAX COOL position (The A/C indicator is held in ON state).
If the result is not as specified, replace the integration control and panel assembly.
- Inspect the REC indicator operation.
- Connect the positive (+) lead from the battery to terminal 1 (IG+) and the negative (-) lead to terminal 20 (GND).NOTE: Inspect the MODE switch in any position except DEF.
- Push the REC button in and check that the indicator lights up.
Standard
SWITCH CONDITIONSwitch Condition Specified Condition Switch ON Indicator illuminates Switch OFF Indicator turns off If the result is not as specified, replace the integration control and panel assembly.
- Under the above condition, connect the positive (+) lead from the battery to terminal 2 (ILL+) and then check that the indicator dims.NOTE: Inspect the MODE switch in any position except DEF.
Standard
SWITCH CONDITIONSwitch Condition Specified Condition Switch ON Indicator dims Switch OFF Indicator turns off If the result is not as specified, replace the integration control and panel assembly.
- Connect the positive (+) lead from the battery to terminal 1 (IG+) and the negative (-) lead to terminal 20 (GND).
- Inspect the temperature control switch operation.
- Connect the positive (+) lead from the battery to terminal 1 (IG+) and the negative (-) lead to terminals 8 (BLW) and 20 (GND).NOTE: Inspect the MODE switch in any position other than DEF and FOOT/DEF.
- Check the A/C indicator and REC indicator operations when the temperature switch is operated.
Standard
TEMPERATURE SWITCH CONDITIONTemperature Switch Condition Specified Condition (A/C indicator and REC indicator) Except MAX A/C Neither indicator illuminates MAX A/C Both indicators illuminate*1 HINT:
*1: The A/C indicator remains, illuminated even after the temperature switch is turned from this position to another. The REC indicator returns to the condition prior to turning the switch to MAX A/C. Press the A/C switch in and check that the indicator turns off.Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
If the result is not as specified, replace the integration control and panel assembly.
- Connect the positive (+) lead from the battery to terminal 1 (IG+) and the negative (-) lead to terminals 8 (BLW) and 20 (GND).
- Inspect MODE switch operation.
- Connect the positive (+) lead from the battery to terminal 1 (IG+) and the negative (-) lead to terminal 20 (GND).
- Check the REC indicator operation when the MODE switch is operated.
Standard
CONDITION REFERENCECondition Specified Condition (REC indicator) MODE switch except DEF REC switch ON ↔ OFF Indicator turns ON ↔ OFF in accordance with REC switch operation MODE switch DEF REC switch ON ↔ OFF Indicator turns off If the result is not as specified, replace the integration control and panel assembly.
- Check the blower switch resistance.