FixVault

On-Vehicle Inspection

  1. CHECK INTAKE AIR CONTROL VALVE ACTUATOR 
    1. Connect the vacuum pump to the actuator.
    2. Apply a vacuum of 39.9 kPa (300 mmHg, 11.8 in.Hg) to the vacuum tank.
    3. 1 minute after applying the vacuum, check that the rod's position is as it was before applying the vacuum.

      If the result is not as specified, replace the actuator.

      Fig 1: Connecting Vacuum Pump To Actuator
      G05289286Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002