Inspection Procedure
- CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU - ELECTRICAL KEY OSCILLATOR)
- Disconnect the E13 ECU connector.
- Disconnect the oscillator connectors.
- Measure the resistance according to the value(s) in the table below.
Standard resistance:
Console
RESISTANCE SPECIFICATION CHARTTester Connection (Symbols) Condition Specified Condition E13-12 (CG5B) - E24-3 (CLGB) Always Below 1 Ω E13-11 (CLG5) - E24-1 (CLG3) Always Below 1 Ω E13-12 (CG5B) - Body ground Always 10 kΩ or higher E13-11 (CLG5) - Body ground Always 10 kΩ or higher Rear Seat
RESISTANCE SPECIFICATION CHARTTester Connection (Symbols) Condition Specified Condition E13-14 (CG6B) - L9-3 (CLGB) Always Below 1 Ω E13-13 (CLG6) - L9-1 (CLG4) Always Below 1 Ω E13-14 (CG6B) - Body ground Always 10 kΩ or higher E13-13 (CLG6) - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK AND REPLACE ELECTRICAL KEY OSCILLATOR
- Replace the electrical key oscillator.
- Check that the entry LOCK/UNLOCK function operates normally.
OK:
Entry LOCK/UNLOCK function operates normally.
OK: END (ELECTRICAL KEY OSCILLATOR IS DEFECTIVE)
NG: Go to next step
- PERFORM ACTIVE TEST BY TECHSTREAM (CERTIFICATION ECU OUTPUT SIGNAL)
- Reconnect the oscillator and the ECU connectors.
- Connect Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the tester on.
- Enter the following menus: Body Electrical / Smart Access / Active Test.
- Perform the Active Test according to the display on the tester.
Smart Access:
SMART ACCESS ACTIVE TEST REFERENCETester Display Test Part Control Range FR Transmitter Indoor electrical key oscillator (console) ON/OFF RR Transmitter Indoor electrical key oscillator (rear seat) ON/OFF - Measure the frequency according to the value(s) in the table below.
Standard:
Console
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection (Symbols) Condition Specified Condition E13-12 (CG5B) - E13-11 (CLG5) During Active Test Frequency is generated (higher than 0 Hz) Rear Seat
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection (Symbols) Condition Specified Condition E13-14 (CG6B) - E13-13 (CLG6) During Active Test Frequency is generated (higher than 0 Hz)
NG: REPLACE CERTIFICATION ECU
OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE