FixVault

Hybrid Mode Select Switch: Inspection

  1. INSPECT HYBRID MODE SELECT SWITCH 
    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      TESTER CONNECTION SPECIFIED CONDITION CHART

      Switch Condition Tester Connection Specified Condition
      Hybrid mode select switch (PWR) 3 - 7 Below 1 Ω
      Hybrid mode select switch (NORM) 3 - 7 10 kΩ or higher
      Press continuously Hybrid mode select switch (SNOW) 1 - 3 Below 1 Ω
      Release Hybrid mode select switch (SNOW) 1 - 3 10 kΩ or higher

      If the resistance value is not as specified, replace the hybrid mode select switch.

      Fig 1: Identifying Terminals Of Hybrid Mode Select Switch Connector
      G05318238Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002