FixVault

Circuit Opening Relay: Inspection

  1. INSPECT CIRCUIT OPENING RELAY 
    1. Check the resistance.
      1. Using an ohmmeter, measure the resistance between the terminals.

        Standard resistance 

        STANDARD RESISTANCE

        Tester Connection Specified Condition
        3-5 10 kΩ or higher
        3-5 Below 1 Ω (Apply battery voltage to terminals 1 and 2)
        Fig 1: Inspecting Circuit Opening Relay
        G04968247Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

        If the result is not as specified, replace the circuit opening relay.