Typical Malfunction Thresholds

TYPICAL MALFUNCTION THRESHOLDS

Either of the following condition is met Condition 1 or 2
1 Frequency that both of following conditions (a) and (b) are met 5 times or more
(a) Engine RPM - Target engine RPM Less than -100 rpm, or more than 150 rpm
(b) Vehicle condition Stop after vehicle was driven at 6 mph (10 km/h) or more
2 Frequency that both of following conditions (a) and (b) are met Once
(a) Engine RPM - Target engine RPM Less than -100 rpm, or more than 150 rpm
(b) IAC flow rate learning value 2 48 L/sec or less, or 11 L/sec or more