FixVault

Speed Sensor: Inspection

  1. INSPECT TRANSMISSION REVOLUTION SENSOR (NT) 
    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

    STANDARD RESISTANCE SPECIFICATION

    Tester Connection Specified Condition (20°C (68°F))
    1 - 2 560 to 680 Ω

    If the resistance value is not as specified, replace the speed sensor.

    Fig 1: Identifying Transmission Revolution Sensor (NT)
    G05826879Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  2. INSPECT TRANSMISSION REVOLUTION SENSOR (SP2) 
    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

    STANDARD RESISTANCE SPECIFICATION

    Tester Connection Specified Condition (20°C (68°F))
    1 - 2 560 to 680 Ω

    If the resistance value is not as specified, replace the speed sensor.

    Fig 2: Identifying Transmission Revolution Sensor (SP2)
    G05826880Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002