  1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL 
  2. REMOVE COOL AIR INTAKE DUCT SEAL  (See REMOVAL )
  3. REMOVE ENGINE ROOM SIDE COVER LH  (See REMOVAL )
  4. REMOVE V-BANK COVER SUB-ASSEMBLY  (See REMOVAL )
  5. REMOVE NO. 1 INLET AIR CLEANER  (See REMOVAL )
  6. REMOVE V-RIBBED BELT  (See REMOVAL )
  7. DRAIN ENGINE COOLANT  (See ON-VEHICLE INSPECTION )
  8. REMOVE RADIATOR INLET HOSE  (See REMOVAL )
  9. REMOVE NO. 2 ENGINE COVER  (See REMOVAL )
  10. REMOVE NO. 2 IDLER PULLEY SUB-ASSEMBLY  (See REMOVAL )
  11. DISCONNECT WIRE HARNESS 
    1. Remove the 3 nuts (A) and disconnect wire harness.
    2. Disconnect the 2 connectors (B).
      Fig 1: Disconnecting Wire Harness Connector
      G05829486Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  12. REMOVE GENERATOR ASSEMBLY 
    1. Remove the terminal cap.
    2. Remove the nut (A) and disconnect the wire harness from terminal B.
    3. Remove the bolt (B) and clamp bracket.
    4. Disconnect the generator connector, and detach the 2 clamps.
      Fig 2: Disconnecting Generator Connector And Clamps
      G05829487Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    5. Remove the nut, and disconnect the generator bracket.
      Fig 3: Removing Bracket Nut
      G05829488Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    6. Remove the 2 bolts and generator.
      Fig 4: Removing Generator Assembly Bolts
      G05829489Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    7. Remove the 2 bolts and 2 generator brackets.
      Fig 5: Removing Generator Brackets Bolts
      G05829490Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002