Inspection Procedure
- INSPECT FUSE (D/C CUT, MPX-B)
- Remove the D/C CUT and MPX-B fuses from the engine room relay block and junction block No 1
- Measure the resistance according to the value (s) in the table below
Standard Resistance
RESISTANCE REFERENCETester Connection Condition Specified Condition D/C CUT fuse Always Below 1 Ω MPX-B fuse Always Below 1 Ω
NG: REPLACE FUSE
OK: Go to next Step
- CHECK COWL SIDE JUNCTION BLOCK RH (POWER SOURCE)
- Install the D/C CUT and MPX-B fuses to the engine room relay block and junction block No. 1
- Disconnect the RK cowl side junction block RH connector.
- Measure the voltage according to the value (s) in the table below
Standard Voltage
VOLTAGE SPECIFICATIONTester Connection Condition Specified Condition RK-5 (+B) - Body ground Always 11 to 14 V
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next Step
- CHECK HARNESS AND CONNECTOR (COWL SIDE JUNCTION BLOCK RH - BODY GROUND)
- Disconnect the RD and RA cowl side junction block RH connectors.
- Measure the resistance according to the value (s) in the table below
Standard Resistance
RESISTANCE REFERENCETester Connection Condition Specified Condition RD-7 (E) - Body ground Always Below 1 Ω RA-5 (-S) - Body ground Always
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (See PROBLEM SYMPTOMS TABLE )