Inspection Procedure
- READ VALUE OF TECHSTREAM (LIGHT CONTROL RHEOSTAT)
- Operate the Techstream according to the display and select "Data List".
OK: Switch condition (ON/OFF) can be switched by actual operation.
Combination Meter:
MEASUREMENT ITEM/RANGE TABLEItem Measurement Item / Range (Display) Normal Condition Diagnostic Note Light Control Up Switch Light control rheostat (UP) switch / ON or OFF ON: Light control rheostat (UP) switch pushed
OFF: Light control rheostat (UP) switch not pushed- Light Control Down Switch Light control rheostat (DOWN) switch / ON or OFF ON: Light control rheostat (DOWN) switch pushed
OFF: Light control rheostat (DOWN) switch not pushed-
NG: Go to step 2
OK: REPLACE NO. 1 METER ECU (See DISASSEMBLY )
- Operate the Techstream according to the display and select "Data List".
- INSPECT LIGHT CONTROL RHEOSTAT
- Remove the rheostat (see REMOVAL ).
- Measure the resistance according to the value(s) in the table below.
Standard resistance
STANDARD RESISTANCE TABLETester Connection Switch Condition Specified Condition 3 (UP) - 5 (E) UP switch Is pushed Below 1 Ω UP switch Is not pushed 10 kΩ or higher 7 (DOWN) - 5 (E) DOWN switch pushed Below 1 Ω DOWN switch Is not pushed 10 kΩ or higher
NG: REPLACE LIGHT CONTROL RHEOSTAT (See REMOVAL )
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (NO. 1 METER ECU - LIGHT CONTROL RHEOSTAT AND BODY GROUND)
- Disconnect the L10 ECU connector.
- Disconnect the L8 rheostat connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
STANDARD RESISTANCE TABLETester Connection Condition Specified Condition L10-8 (RHUP) - L8-3 (UP) Always Below 1 Ω L10-7 (RHDW) - L8-7 (DOWN) L8-5 (E) - Body ground L10-8 (RHUP) or L8-3 (UP) - Body ground Always 10 kΩ or higher L10-7 (RHDW) or L8-7 (DOWN) - Body ground
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: REPLACE NO. 1 METER ECU (See DISASSEMBLY )