Door Control Switch: Inspection
- INSPECT DOOR CONTROL SWITCH ASSEMBLY
- Measure the resistance according to the value (s) in the table below
Standard resistance
RESISTANCE SPECIFIED CONDITIONTester Connection Switch Condition Specified Condition 2 (L) - 3 (E) Lock Below 1 Ω 2 (L) - 3 (E) 4 (UL) - 3 (E) OFF 10 kΩ or higher 4 (UL) - 3 (E) Unlock Below 1 Ω Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
If the result is not as specified, replace the control switch assembly.
- Apply battery voltage and check that the indicator (LED) illuminates.
OK
MEASUREMENT SPECIFIED CONDITION CHARTMeasurement Condition Specified Condition Battery positive (+) → Terminal 5 (ILL+) Indicator (LED) illuminates Battery negative (-) → Terminal 3 (E) Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
If the result is not as specified, replace the door control switch assembly
- Measure the resistance according to the value (s) in the table below